72rallye  



Joined: 08 Apr 2023
Posts: 18
Location: San Diego, CA, USA

PostPosted: Sun Jul 28, 2024 9:25 pm    Post subject: Reply with quote

Gut beobachtet! I don't know what happened. Maybe I made a typo, maybe it was one of those transistors that are simply labeled "C328", and one has to guess if it means BC328 (pnp) or 2SC328 (npn).
In my view the circuit needs an npn transistor to work properly. I am going to check the PCB again, and then update the drawing. Unfortunately, I won't have access to the relay for many weeks, so it'll take a while.

There is another issue with the Zener diode Z2. It was labeled "200", but I couldn't determine the model number. It is unlikely that the breakdown voltage is 200V, since the ignition coil probably cannot generate such a high voltage when the current shuts off. A voltage of 20.0V would be very reasonable.

Thomas
_________________
81 931, 86 951, 86 928 5spd, 75 911S coupe
Back to top
View user's profile Send private message
Raize  



Joined: 18 Sep 2013
Posts: 281
Location: Scotland

PostPosted: Mon Jul 29, 2024 2:56 am    Post subject: Reply with quote

Whoever can remanufacture the fuel pump relay will be rich!

Well, by 924 standards.
Back to top
View user's profile Send private message
Siegfrieds  



Joined: 18 Dec 2019
Posts: 6
Location: Germany

PostPosted: Mon Jul 29, 2024 7:17 am    Post subject: Reply with quote

Ok, thanks for your correction.

Striking rich is only possible with high numbers of products.
Who needs a relay ?

for the 924 as of 1975-1978 ?
fir the 934 as of 1979 - ?
_________________
SiegfriedS
1976 924
Back to top
View user's profile Send private message
72rallye  



Joined: 08 Apr 2023
Posts: 18
Location: San Diego, CA, USA

PostPosted: Tue Aug 27, 2024 5:26 am    Post subject: Reply with quote

>>>>>BC 328 is a pnp relais, the circuit shows BC328 as a npn one. Mistake…probablyanother BC 327 .

There is nothing wrong with the circuit diagram. The npn transistor in the diagram is labeled BC238B, and NOT BC328.

I checked the Zener diode Z2 again. The two relays that I own have different components in it. One has an ITT ZY100 diode, and the other a ZY200. The listed corresponding breakdown voltages are 100V and 200V. This seems very high to me, but so be it. I verified that the breakdown voltage is definitely larger than 30V, which is how high my test setup went.

Btw, the second relay has a BC548B installed, not a BC238B. Not a problem, since they are only being used as a switch, and not as an analog device.

Thomas
_________________
81 931, 86 951, 86 928 5spd, 75 911S coupe
Back to top
View user's profile Send private message
Siegfrieds  



Joined: 18 Dec 2019
Posts: 6
Location: Germany

PostPosted: Tue Aug 27, 2024 6:03 am    Post subject: Reply with quote

Ok, understood, thank you!
_________________
SiegfriedS
1976 924
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic   Reply to topic    924Board.org Forum Index -> General Discussions All times are GMT + 11 Hours
Goto page Previous  1, 2, 3, 4
Page 4 of 4

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group